Electrical Equipment
chap. 6
6-12
Release 00 2002-09
Atlantic 500
RPM SENSOR CHECK
With motor off:
• Disconnect the three-way connector (1) and take
measurements.
• With a multimeter (scale x 100 Ω) measure the
resistance between the sensor terminals,
observing polarity (see diagram).
Standard value: 680
ΩΩ
ΩΩ
Ω ± 10%
• If the resistance is infinite or different from the
prescribed value, the sensor must be replaced.
-
+
Ω
+